Milesight AM104 LoRaWAN Indoor Ambience Monitoring Sensor for measuring temperature, humidity, motion and light
Milesight AM104 consists of multiple smart LoRaWAN sensors that are built specifically for indoor ambient measurements. It has a clean and modern design that makes it discrete in indoor ambience.
Product Description
Milesight AM104 consists of multiple smart LoRaWAN sensors that are built specifically for indoor ambient measurements. It has a clean and modern design that makes it discrete in indoor ambience.
Product Description
|
AM100 Series
|
AM104-915M
|
||
Hardware
|
Frequency
|
EU433/CN470/RU864/IN865/EU868/US915/AU915/KR920/AS923
|
||
Mode
|
OTAA/ABP
|
|||
Power Supply
|
2 × alkaline AA batteries
|
|||
Battery Lifetime
|
1.2 years (SF7)
0.8 years (SF12)
|
|||
Sensors
|
PIR, Light, CO2, TVOC, Barometric Pressure
|
Quick Details of AM100 Series LoRaWAN Sensor
_________________________________________________________________
Product Highlights
√ Long Battery Lifetime
√ E-Ink Screen Display
√ Multiple Sensors in One
√ Easy to Use - NFC Configuring
Develop Device-to-Cloud Connection
The Milesight IoT Cloud is a comprehensive cloud service provides unparalleled levels of vertical integration with LoRaWAN Sensor series and LoRaWAN Gateway to link vertical, back-end applications to remote assets.
Partners
Success Stories
Specifications
|
|
AM107
|
AM104
|
||
Hardware
|
Frequency
|
CN470/RU864/IN865/EU868/US915/AU915/KR920/AS923
|
|
||
Regular
|
20dBm
|
||||
Sensitivity
|
-147dBm @300bps
|
||||
Mode
|
OTAA/ABP
|
||||
Power Supply
|
2 × alkaline AA batteries
|
||||
Battery Lifetime
|
1 year (SF7)
0.9 year (SF12) |
1.5 years (SF7)
1.2 years (SF12)
|
|||
Sensors
|
Temperature
|
Range
|
-40°C to + 70°
|
|
|
Accuracy
|
±0.3°C (0°C – 70°C), ±0.6°C (-40°C – 0°C)
|
||||
Humidity
|
Range
|
0% to 100% RH
|
|||
Accuracy
|
±3% RH (10% – 90%), ±5% RH (0% – 10%, 90% – 100%)
|
||||
PIR
|
Detection Area
|
94 ° Horizontal, 82 ° Vertical
|
|||
Detection Distance
|
5 m
|
||||
Light
|
Range
|
60000 lux (Visible + IR, IR)
|
|||
Accuracy
|
±30%
|
||||
CO2
|
Range
|
400 – 5000 ppm
|
N/A
|
||
Accuracy
|
±30 ppm or ±3 % of reading
|
||||
TVOC
|
Range
|
0 – 60000 ppb (total VOC)
|
|||
Accuracy
|
±15 % of reading
|
||||
Long-term Stability
|
1.3 % accuracy drift per year
|
||||
Barometric Pressure
|
Range
|
300 – 1100 hPa (-40°C – 85°C)
|
|||
Accuracy
|
±1 hPa
|